Home > Products center > Flowmeter >Insertion Electromagnetic Flowmeter

Pipeline valve

Insertion Electromagnetic Flowmeter

2017-09-08

插入式电磁流量计.jpg

ProductName:Insertion Electromagnetic Flowmeter

ProductNumber:HMFI

Application:
It is used to measure the volumetric flow of the conductive liquid and slurry in the closed conduits in such industries as water & wastewater, chemical, petroleum, metallurgical, power, pharmaceutical, food, beverage, pulp & paper, etc.

Features:
Plug-in probes, suitable for permanent or temporary installation;
■ Low price compared to classic on line device, the price independent of pipe diameter;
■ Hot tap capability, enable to install or maintain without stopping water supply;
■ Suitable nominal size up to 2000 mm。


Main technical parameter:
Insert length: 163 mm、263 mm、363 mm、463 mm
Nominal Size: DN150 ~ DN 3000
Nominal Pressure: 0.6、1.0、1.6 MPa
Structure: Compact or remote
Fluid conductivity:≥20μS/㎝
Medium temperature: ≤80℃、≤120℃
Ambient temperature: -20℃ ~ +55℃
Accuracy:1.5
Max. velocity of flow: 10 m/s
Electrode material: 316L,Hastelloy alloyC,Hastelloy alloyB
Probe material: 316L +PTFE
Protection class: IP 65,IP 67,IP 68
Ex-proof mark: Ex deⅡCT6
Power supply: 85 VAC~260 VAC、16VDC ~ 36 VDC
Display: 3lines with backlit LCD for display, keypad version or red-light version for programming.
Output: Programmable 0/4 mA ~ 20 mA,Pulse, Frequency,Contact
Input: Contact
Protocol: RS232C,RS485
Detection alarm: Current output, Pulse / Frequency output, Upper / Lower limit Alarm, Empty pipe,Flow direction etc.



Other products